Work out how much PEX/PERT pipe a room needs for water underfloor heating — from the room size, pipe spacing, and the run to the manifold — plus how many loops, how much water, and how many coils to buy.

Room dimensions

m
m
200 mm

Manifold & buffer

m
10 %

Loops, water & coils

m

Pre-filled for the pipe size: about 100 m for 16 mm and 120 m for 20 mm are the commonly cited maximums. Many installers design to 80–90 m on 16 mm for an easier-to-balance system — lower it if you want that margin.

Room
Pipe needed

Before you buy

  • This is an area-over-spacing estimate, not an exact turn-by-turn layout — it doesn't model the precise geometry of a "serpentine" or "spiral" laying pattern, so leave a sensible buffer for turns.
  • Serpentine vs. spiral changes how evenly the floor heats, not the total pipe length this formula gives — pick the pattern for heat distribution, not to save pipe.
  • Each loop needs its own outlet pair on the manifold — check your manifold has at least as many ports as the loop count. The loop count here is a length-limit estimate, not a hydraulic design: flow rates, pressure drop, and balancing are still the installer's job.
  • Buy coils so every loop comes out of a single coil in one piece — a joint buried in the screed is the classic underfloor-heating failure point, which is why the coil count works in whole loops, not just metres.
94.6 m
Total pipe needed
16.0 m²
Room area
6.0 m
Manifold runs (there and back, all loops)
1 × 94.6 m
Loops × loop length
10.7 L
Water in the pipe
1 × 200 m
Coils to buy
left over 105.4 m

How this is calculated

The pipe covering the floor area works out to room area divided by pipe spacing — the standard formula used across underfloor heating calculators. The room is then split into the smallest number of equal loops that each stay under the loop limit; every loop runs to the manifold and back on its own, so the manifold distance is added twice per loop, and a buffer is added on top for turns and trimming (with a single loop this is exactly the classic formula). Water volume is the total pipe length times the pipe's inner cross-section. Coils are counted in whole loops, because a loop should never be jointed inside the floor. Actual usage can run a bit higher for a spiral pattern with tight corner turns — that's exactly what the buffer is for.

Common questions

Why is this an estimate, not an exact figure?

Because the area ÷ spacing formula assumes the pipe perfectly fills the floor in parallel rows — it doesn't account for the exact length used in the turns at each end of a row, which depends on the laying pattern and the room's exact shape. That's a small but real difference, which is what the buffer percentage exists to absorb.

Serpentine or spiral — which should I choose?

Whichever suits your installation — this formula gives the same total length either way, since both cover the same area at the same spacing. The real difference between them is heat distribution: spiral (also called "snail") tends to spread heat more evenly across the floor than a simple back-and-forth serpentine.

How many loops does a room need?

As many as it takes to keep every loop under the loop limit — about 100 m is the commonly cited maximum for 16 mm pipe and 120 m for 20 mm, with many installers designing to 80–90 m on 16 mm. The calculator splits the room into the smallest number of equal loops that fit, counting each loop's own run to the manifold and back. It's a length-limit estimate: flow rates, pressure drop, and balancing between loops still need checking against your manifold and pump.

How much water is in an underfloor heating loop?

Pipe length times the inner cross-section: 16×2.0 mm pipe (12 mm inside) holds about 0.113 L per metre, 16×2.2 mm (11.6 mm inside) about 0.106 L/m, and 20×2.0 mm (16 mm inside) about 0.201 L/m. The default 4×4 m room needs 94.6 m of 16×2.0 mm pipe — about 10.7 L. Add the manifold, boiler, and connecting pipework separately when sizing an expansion vessel or filling the system.

How many coils of pipe should I buy, and why not just divide by the coil length?

Because each loop has to come off a single coil in one piece — a joint buried in the screed is where underfloor heating systems fail. So the calculator fits whole loops into each coil (a 200 m coil holds two 94.6 m loops, not 2.1) and only then counts coils and the leftover. If a single loop is longer than the coil, it warns you to pick a longer one instead of quietly counting metres.